Heavy Duty Agriculture Chiller Price

Origin: China
Application: Agriculture
Capacities: 2hp~140hp
Payment Terms: TT , LC , Others
> Features > Parameters > Catalog


Water to water series

The master module can work independently or together with up to 7 slave modules, flexible design, stable performance, easy maintenance.


Reusable: using solar energy stored in earth as cooling & heating source.


Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.


3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.


Shell and tube type evaporator, factory insulated with flexible close cell material.

Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.

The refrigerant circuit is complete with filter drier, direct expansion valve, high and low pressure switch.


Acting as multi-function unit such as cooling, heating, with heat recovery function producing hot water for domestic use.

LCD display as standard

Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc. 


Electric panel

consists of:

Compressor breaker

Compressor contactor

Phase sequence relay

Control circuit breaker

Microprocessor with function display


Optional

Desuperheater as optional

Electronic controller with BMS system.


Specifications

Model WW80 WW120 WW160

Water cooled conditions
Cooling capacity kW 80 120 160
Ton 22.9 34.2 45.7
Cooling power input(kW) 15.5 23.5 31.0

Compressor
Type Danfoss/Copeland scroll compressor
Power input 380V/3N~50Hz
Qty 2 3 4



User side heat exchanger
Type Shell and tube heat exchanger
Water resistance(kpa) 40-60
Fouling factor(m²·oC/kw) 0.086
Pipe size (mm) DN65 DN80
Connection type Flange
Water flow rate(m³/h) 13.8 20.5 27.5



Source side heat exchanger
Type Shell and tube heat exchanger
Water resistance(kpa) 40-60
Fouling factor(m²·oC/kw) 0.086
Pipe size (mm) DN65 DN80
Connection type Flange
Water flow rate(m³/h) 16.5 24.5 32.8

Dimension
Length(mm) 2110 2110 2530
Width(mm) 620 620 650
Height(mm) 1365 1365 1410
Noise level≤dB(A) 67 67 67
Unit weight(kg) 560 800 1050

Note: 

1. Cooling condition: User side water inlet/outlet 12oC/7oC, Source side water inlet/outlet 30oC/35oC.

2.Power supply: 3P-380V-50Hz.