Food Industry Chiller Service

Mode: Cooling
Application: Food Industry
Capacities: 2hp~40hp
Refrigerant: R410A/R134A/R407C/R404A/R507
> Features > Parameters > Catalog


Air to water series

Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.


3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.


External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.


Evaporator built with high efficiency shell and tube type heat exchanger, factory insulated with flexible close cell material. 


Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.


Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve, high & low pressure switch. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.


Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.


Electric panel consist of: 

compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit)

Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system. 


Optional

Paddle flow switch;

Metallic filter for hydraulic circuit;

Water pump;

Rubber antivibration mounting.

Heat recovery functions


Water to water series

The master module can work independently or together with up to 7 slave modules, flexible design, stable performance, easy maintenance.


Reusable: using solar energy stored in earth as cooling & heating source.


Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.


3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.


Shell and tube type evaporator, factory insulated with flexible close cell material.

Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.

The refrigerant circuit is complete with filter drier, direct expansion valve, high and low pressure switch.


Acting as multi-function unit such as cooling, heating, with heat recovery function producing hot water for domestic use.

LCD display as standard

Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc. 


Electric panel

consists of:

Compressor breaker

Compressor contactor

Phase sequence relay

Control circuit breaker

Microprocessor with function display


Optional

Desuperheater as optional

Electronic controller with BMS system.


Specifications

Model Unit AW8 AW10 AW12 AW16 AW20 AW25 AW30 AW35 AW40 AW50
Cooling *  
 
Cooling capacity
kW 8.7 10.7 12.5 15.8 21.5 24.8 30 35.6 41 50.6
Ton 2.5 3.1 3.6 4.5 6.1 7.1 8.6 10.2 11.7 14.5
Cooling input (without water pump) kW 3.2 4.01 4.56 5.79 8.2 9.03 9.39 13.2 15.02 18.8
EER / 2.72 2.67 2.74 2.73 2.62 2.75 3.19 2.7 2.73 2.69
Heating **  
 
Heating capacity
kW 10.3 13.5 14 17.8 26.3 29 34 41.8 47.2 60
Ton 2.9 3.9 4 5.1 7.5 8.3 9.7 11.9 13.5 17.1
Heating input (without water pump) kW 3.5 4.55 4.58 5.81 8.7 9.23 9.43 14.3 15.57 20.45
COP / 2.94 2.97 3.06 3.06 3.02 3.14 3.61 2.92 3.03 2.93
Hermetic compressor  
Type / Scroll
Quantity/ circuit / 1 1 1 1 2/2 2/2 2/2 2/2 2/2 2/2
Evaporator  
Type / Plate heat exchanger
Water flow m3/h 1.5 1.8 2.1 2.7 3.7 4.3 5.2 6.1 7.1 8.7
Water side pressure drop kPa 33 33 33 36 38 39 42 50 52 52
Water connection size mm DN25 DN25 DN25 DN25 DN40 DN40 DN40 DN40 DN40 DN40
Circulating pump  
Power input kW 0.4 0.4 0.35 0.35 0.75 0.75 0.92 ------ ------ ------
Axial fans  
Quantity Nr. 1 1 1 2 1 1 1 2 2 2
Airflow m3/h 4500 4500 4500 9000 9000 9000 12580 17000 17000 22000
Overall dimension  
Length mm 1250 1250 1250 1250 1600 1600 1600 2000 2000 2000
Width mm 452 452 452 452 900 900 900 900 900 900
Height mm 1180 1180 1180 1180 1080 1080 1080 1080 1080 1080
Noise level *** dB(A) 58 58 60 64 66 66 68 70 70 70
Net weight kg 145 145 150 190 270 290 310 360 380 465

*Ambient temperature 35ºC; evaporator water in/out 12/7 ºC;

** Ambient temperature DB 7 ºC, WB 6 ºC; condenser water in/out temperature 40/45 ºC;

*** In the nominal water flow condition the pressure drop is between this range.

**** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.


Model Unit AW60 AW68 AW88 AW88 AW108 AW108 AW128
Capacity  
 
Cooling capacity*
kW 60 68 88 88 108 108 132
Ton 17.1 19.4 25.1 25.1 30.9 30.9 37.8
Cooling power input* kW 22.34 20.94 27.7 26.62 35.28 38.91 46.24
 
Heating capacity**
kW 62 70 95 95 115 119 150
Ton 17.7 20 27.1 27.1 32.9 34 42.9
Heating power input** kW 22.42 21.1 27.32 26.25 35.28 39.1 46.24
Compressor  
Type / Scroll
Qty/refrigerant circuit Nr. 4/4 2/2 2/2 4/4 3/3 6/6 4/4
Axial fan  
Quantity Nr. 2 2 2 2 3 3 2
Airflow m3/h 24000 24000 35800 35800 39000 39000 48000
Evaporator  
Type / S T S S S S S
Water flow m3/h 10.3 11.7 15.1 15.1 17.2 17.2 22.7
Water side pressure drop *** kPa 43 43 42 42 41 41 41
Connect pipe DN 65 125 65 65 65 65 80
Noise level**** dB(A) 70 74 72 72 73 73 77
Dimensions  
Length mm 1980 2110 2200 2200 3100 3100 2200
Width mm 1005 1080 1270 1270 1050 1050 1560
Height mm 1750 1900 2050 2050 1900 1900 2160
Net weight kg 700 800 950 920 1000 1000 1450

*Ambient temperature 35ºC; evaporator water in/out 12/7 ºC;

** Ambient temperature DB 7 ºC, WB 6 ºC; condenser water in/out temperature 40/45 ºC;

*** In the nominal water flow condition the pressure drop is between this range.

**** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.


Model WW80 WW120 WW160

Water cooled conditions
Cooling capacity kW 80 120 160
Ton 22.9 34.2 45.7
Cooling power input(kW) 15.5 23.5 31.0

Compressor
Type Danfoss/Copeland scroll compressor
Power input 380V/3N~50Hz
Qty 2 3 4



User side heat exchanger
Type Shell and tube heat exchanger
Water resistance(kpa) 40-60
Fouling factor(m²·oC/kw) 0.086
Pipe size (mm) DN65 DN80
Connection type Flange
Water flow rate(m³/h) 13.8 20.5 27.5



Source side heat exchanger
Type Shell and tube heat exchanger
Water resistance(kpa) 40-60
Fouling factor(m²·oC/kw) 0.086
Pipe size (mm) DN65 DN80
Connection type Flange
Water flow rate(m³/h) 16.5 24.5 32.8

Dimension
Length(mm) 2110 2110 2530
Width(mm) 620 620 650
Height(mm) 1365 1365 1410
Noise level≤dB(A) 67 67 67
Unit weight(kg) 560 800 1050

Note: 

1. Cooling condition: User side water inlet/outlet 12oC/7oC, Source side water inlet/outlet 30oC/35oC.

2.Power supply: 3P-380V-50Hz.

Request For Quotation