Amrta rooftop units can be installed with a gas burner. As one of the helper warming gadgets, it permits the rooftop units to warm without running the refrigeration framework or just with some portion of it to accomplish a superior of vitality sparing at lower surrounding temperature in winter and to lessen hugely the warming working expenses uniquely for where the gaseous petrol is less expensive than power.
The gas heating modular use a safe and reliable atmospheric gas burner made of aluminized steel tube heat exchanger designed to offer maximum heat transfer and 92% efficiency (PCI%). It runs with natural gas in an operating range of 1.3-2.6KPa. The standard gas module offers 2 stages of control which helps in improving space comfort by avoiding large supply air temperature deviations. The airflow rate in the burner is controlled as the gas flow is being reduced maintaining the burner to its highest efficiency level.
S: 30kW
M: 50kW
L: 100kW
3 modules are available, which can provide separately 30kW, 50kW and 100kW heating capacity in standard working condition according to your different heating requirements. Where more capacity is required a modulating version is available with flexible combination. For safety reasons, the rooftop air conditioner unit with gas heating can’t be installed inside a technical room.
Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Direct expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
Centrifugal fan
Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
Front, side and underside air discharge of the treatment unit.
High external pressure, long air supply distance.
Electric panel
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
Easy operation line controller
Cooling/Heating/Auto
Error indication
Timing on/off
Optional
Economizer with fresh, return air dampers and fresh air hood
Free cooling function for low ambient temperature
Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
Heat recovery to 100%
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply/return air configurations
Upgraded plug fan
G4 filter, plate and bag filter
Technical Data
* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C.
Heating: room air temperature 21.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.