Pharmaceutical Industry Chiller

Available in: Cooling
Capacities: 2hp~140hp
Refrigerant: R410A/R134A/R407C/R404A/R507
Payment Terms: TT , LC , Others
> Features > Parameters > Catalog


Features

The compressor

The unit is equipped with semi-hermetic screw compressor, compared with the piston compressor, semi-hermetic screw compressor has two advantages:

• Less parts(About 1/3 of the piston compressor), simple structure, less wearing parts, high reliability and long life.

• Compressor suction and exhaust uniform, exhaust temperature is low, vibration is small, not sensitive to wet compression, anti-liquid strike ability.


Tube-fin air-cooled condenser

The tube-fin air-cooled condenser adopts the inverted "V" type layout, on the one hand, it improves the space utilization ratio, increases the heat exchange area, on the other hand, it improves the airflow and heat transfer efficiency, so that improve the unit's cooling and heating capacity.


Throttling equipment

For expansion valve, we select the most advanced products, with a compact overall design, rugged stainless steel diaphragm, and in a wide range of operating conditions to provide stable and accurate control.


Tube-shell evaporator

Using shell and tube structure, the outside is proceeded with fire-retardant,waterproof insulation materials, water side of the working pressure is 1.0MPa.

Evaporator with PVC plastic water board, corrosion resistance. Chilled water along the diaphragm up and down circuitous flow, in order to increase the spoiler effect to improve the evaporator heat transfer capacity.

Using the latest DAC corrugated spiral high efficiency heat transfer tubes, strengthen the fluorine side heat transfer capacity, improve the heat transfer coefficient to ensure that the unit good refrigeration and heating performance.


Electronic control

Air-cooled hot and cold water unit uses a microcomputer as the core of the control system, the control system control precision, anti-interference ability to ensure that the unit safe, reliable and economical operation.

Energy regulation automatic control can make the unit always in the best economic mode point efficient operation.

Protection function complete unit with overload, short circuit protection, frost protection, high and low voltage protection, overheating protection and other functions.


Technical Data

Model Unit AW8 AW10 AW12 AW16 AW20 AW25 AW30 AW35 AW40 AW50
Cooling *  
 
Cooling capacity
kW 8.7 10.7 12.5 15.8 21.5 24.8 30 35.6 41 50.6
Ton 2.5 3.1 3.6 4.5 6.1 7.1 8.6 10.2 11.7 14.5
Cooling input (without water pump) kW 3.2 4.01 4.56 5.79 8.2 9.03 9.39 13.2 15.02 18.8
EER / 2.72 2.67 2.74 2.73 2.62 2.75 3.19 2.7 2.73 2.69
Heating **  
 
Heating capacity
kW 10.3 13.5 14 17.8 26.3 29 34 41.8 47.2 60
Ton 2.9 3.9 4 5.1 7.5 8.3 9.7 11.9 13.5 17.1
Heating input (without water pump) kW 3.5 4.55 4.58 5.81 8.7 9.23 9.43 14.3 15.57 20.45
COP / 2.94 2.97 3.06 3.06 3.02 3.14 3.61 2.92 3.03 2.93
Hermetic compressor  
Type / Scroll
Quantity/ circuit / 1 1 1 1 2/2 2/2 2/2 2/2 2/2 2/2
Evaporator  
Type / Plate heat exchanger
Water flow m3/h 1.5 1.8 2.1 2.7 3.7 4.3 5.2 6.1 7.1 8.7
Water side pressure drop kPa 33 33 33 36 38 39 42 50 52 52
Water connection size mm DN25 DN25 DN25 DN25 DN40 DN40 DN40 DN40 DN40 DN40
Circulating pump  
Power input kW 0.4 0.4 0.35 0.35 0.75 0.75 0.92 ------ ------ ------
Axial fans  
Quantity Nr. 1 1 1 2 1 1 1 2 2 2
Airflow m3/h 4500 4500 4500 9000 9000 9000 12580 17000 17000 22000
Overall dimension  
Length mm 1250 1250 1250 1250 1600 1600 1600 2000 2000 2000
Width mm 452 452 452 452 900 900 900 900 900 900
Height mm 1180 1180 1180 1180 1080 1080 1080 1080 1080 1080
Noise level *** dB(A) 58 58 60 64 66 66 68 70 70 70
Net weight kg 145 145 150 190 270 290 310 360 380 465


*Ambient temperature 35ºC; evaporator water in/out 12/7 ºC;

** Ambient temperature DB 7 ºC, WB 6 ºC; condenser water in/out temperature 40/45 ºC;

*** In the nominal water flow condition the pressure drop is between this range.

**** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.


Model Unit AW60 AW68 AW88 AW88 AW108 AW108 AW128
Capacity  
 
Cooling capacity*
kW 60 68 88 88 108 108 132
Ton 17.1 19.4 25.1 25.1 30.9 30.9 37.8
Cooling power input* kW 22.34 20.94 27.7 26.62 35.28 38.91 46.24
 
Heating capacity**
kW 62 70 95 95 115 119 150
Ton 17.7 20 27.1 27.1 32.9 34 42.9
Heating power input** kW 22.42 21.1 27.32 26.25 35.28 39.1 46.24
Compressor  
Type / Scroll
Qty/refrigerant circuit Nr. 4/4 2/2 2/2 4/4 3/3 6/6 4/4
Axial fan  
Quantity Nr. 2 2 2 2 3 3 2
Airflow m3/h 24000 24000 35800 35800 39000 39000 48000
Evaporator  
Type / S T S S S S S
Water flow m3/h 10.3 11.7 15.1 15.1 17.2 17.2 22.7
Water side pressure drop *** kPa 43 43 42 42 41 41 41
Connect pipe DN 65 125 65 65 65 65 80
Noise level**** dB(A) 70 74 72 72 73 73 77
Dimensions  
Length mm 1980 2110 2200 2200 3100 3100 2200
Width mm 1005 1080 1270 1270 1050 1050 1560
Height mm 1750 1900 2050 2050 1900 1900 2160
Net weight kg 700 800 950 920 1000 1000 1450


*Ambient temperature 35ºC; evaporator water in/out 12/7 ºC;

** Ambient temperature DB 7 ºC, WB 6 ºC; condenser water in/out temperature 40/45 ºC;

*** In the nominal water flow condition the pressure drop is between this range.

**** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.

Request For Quotation