CE Certificate DC inverter Water Chilled Ceiling Fan Coil Unit for Air Conditioning

Air Flow: 340m³/h~2380m³/h
Application: Commercial
Origin: China
Payment Terms: TT , LC , Others
> Features > Parameters > Catalog


Features

Solid development 

Packaging of Amrta fan curl units will be aroused steel board. What's more, the condensate container is treated by expelled consistent innovation to forestall the spillage. Fire evaluated warm protection is connected to the condensate skillet essentially. Development of the units is durable and perpetual. 


High proficiency 

Curls will be created by Φ9.25mm cooper tubes and hydrophilic aluminum blades. Cylinders are ventured into the balances precisely to affirm the warmth move effectiveness. Fans will be high wind stream rate and low clamor plan. Also, metal headers of copper tubes well circulate water stream arrangement to guarantee ideal warmth move effectiveness. 


Low commotion and working expense 

Fans will be extraordinarily planned with larger than usual excited multi-edge divergent wheel, working with low commotion, high static weight and wind current rate. Furthermore, hello there static, lasting split capacitor engines will be industrial facility balance tried for evidence the high effectiveness and very activity. 


Simple support 

Engines will be manufactured with moving bearing and extinguished and tempered steel shaft with antirust treated. Three-speed or LCD indoor regulator is advantageous to control the wind stream and room temperature. 


Low establishment cost 

Units will be low-weight plan. Channel lines and wires are simple for association. The water association heading and air return are variable as per the site necessities. 


Specification

Loop: high effectiveness heat move execution 


Curls will be made by Φ9.25mm cooper cylinders and sine-wave hydrophilic aluminum balances. Copper tubes are precisely extended to bond with aluminum balances. Considering water stream arrangement and the presentation of warmth move, headers will be manufactured of metal material. 

Packaging: solid structure and exquisite plan 

Packaging will be built by expelled electrify steel board (class 1), fitting for solid order. 

Channel dish: uncommon plan for no spillage 

Condensate channel skillet will be created by excellent board with punch framing and hot-plunge preparing paint treated. PE protection with thickness of 7 mm is intended to firmly bond with channel container with the advantage of simple assembling, hostile to spillage and rich component in the long run expanding the channel skillet life. 


Engine: high proficiency and low force utilization 

Engines will comprise of low clamor perpetual capacitor engines and absolute airtight moving holding on for lasting greased up. The base of engine will be detached by elastic mount to limit the vibration and activity commotion. 


Fans: low acoustic level 


Fans will be furnished with effective, low commotion, multi-edge radial fan with curiously large fan wheel, and will be produced with aroused steel board for well unique equalization execution. 


Regulator: simple and agreeable 

Regulator will be simple with inconsistent speed of fans and agreeable interface for clients. AMT801 regulator is utilized as discretionary permitting clients to choose working mode and fan speed physically, to set the temperature by utilizing the handle. Or on the other hand AMT806 Series Thermostats is progressed control as discretionary utilizing computerized LCD show and EL Backlight, permitting clients: to identify the room temperature with NTC sensor and contrasts it and the set-point for consequently keeping the room temperature stable; to modify naturally 3-speed of fan; to spare information and memory with yield solid by transfer. 


Alternatives 

Electric radiator Removable aluminum channel 

High static weight fan Stainless steel condensate container 

Air return box (underneath return or back return) Controller: AMT801 regulator 

Natural air gulf for air return box or AMT806 Series Thermostats

 

Progressed Option (Upgraded EC Fan Coil Unit) 

Representing by remarkable vitality sparing impact, the EC fan curl unit spares over 30% vitality contrasted and customary fan loop units at a similar engine speed. At the point when the fan engine works at mid or low speed, the impact of vitality sparing is more noteworthy. 

Astute control by standard savvy indoor regulator, with microchip innovation, adequately allows to accomplish the stepless speed variety with programmed change of engine charges and electrical dampers by distinguishing the encompassing temperature and the set-point, essentially improve vitality sparing, solace and unwavering quality. 


Customary fan curl unit is typically working in 3-variable-speed with a scope of ±2oC for room temperature vacillation. The redesigned EC fan loop unit highlights persistent programmed alteration innovation and stepless speed variety, which controls the room temperature vacillation under ±0.5oC. 


Working with little vibration and any electromagnetic commotion guarantees a calm activity and improves the serenity and solace for room condition. 


Utilizing electronic replacement module, decreasing the scraped area of electrical parts, makes EC fan curl units with higher caliber and longer life than conventional AC engine fan loop units.


Technical Data (2pipes 3rows)

Model                      FCU34 FCU51 FCU68 FCU85 FCU102 FCU136 FCU170 FCU204 FCU238
Air flow H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M m3/h 255 383 510 638 765 1020 1275 1530 1785
L m3/h 170 255 340 425 510 680 850 1020 1190
Total cooling capacity * H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1440 2160 2880 3600 4320 5760 7200 8640 10080
L W 1170 1755 2340 2925 3510 4680 5850 7020 8190
Sensible cooling capacity* H m3/h 1307 1961 2615 3268 3922 5229 6537 7844 10300
M m3/h 1177 1765 2353 2942 3530 4706 5883 7060 8500
L m3/h 1059 1588 2118 2647 3177 4236 5295 6354 7460
Heating capacity* H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W 2160 3240 4320 5400 6480 8640 10800 12960 15120
L W 1857 2633 3510 4388 5265 7020 8775 10530 11340
Standard external pressure Pa 12 12 12 12 12 12 12 12 12
Power input 12Pa W 35.2 46 57.4 69 86 123 160 189 228
30Pa W 39.5 55 66.9 82 100 136 175 211 247
50Pa W 49.5 59 85.4 93 108 155 188 236 297
Sound pressure Level** 12Pa dB(A) 37 39 41 43 45 46 48 50 52
30Pa dB(A) 40 42 44 46 47 48 50 52 54
50Pa dB(A) 42 44 46 47 49 50 52 54 56
Net weight kg 10.5 14.6 16 16.5 18.5 23.5 25.5 30.5 35.5
Water flow rate m3/h 0.4 0.51 0.71 0.92 1.05 1.4 1.75 2.1 2.5
Water pressure drop kPa 20 20 25 30 35 40 40 45 50
Water connections Inch RC 3/4
Drain pipe Inch RC 3/4
Fan motor quantity Nr. 1 1 1 1 1 2 2 2 2
Fan quantity Nr. 1 2 2 2 2 3 4 4 4
Max. working pressure Mpa 2
Power supply / 220V/1Ph/50Hz


Technical Data (4pipes 3+1rows)

Model                      FCU34 FCU51 FCU68 FCU85 FCU102 FCU136 FCU170 FCU204 FCU238
Air flow H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M m3/h 255 383 510 638 765 1020 1275 1530 1785
L m3/h 170 255 340 425 510 680 850 1020 1190
Total cooling capacity * H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1440 2160 2880 3600 4320 5760 7200 8640 10080
L W 1170 1755 2340 2925 3510 4680 5850 7020 8190
Sensible cooling capacity* H m3/h 1307 1961 2615 3268 3922 5229 6537 7844 10300
M m3/h 1177 1765 2353 2942 3530 4706 5883 7060 8500
L m3/h 1059 1588 2118 2647 3177 4236 5295 6354 7460
Heating capacity* H W 810 1215 1620 2025 2430 3240 4050 4860 6300
M W 729 1094 1458 1823 2187 2916 2645 4374 5040
L W 656 984 1312 1640 1968 2624 3281 3937 3780
Standard external pressure Pa 12 12 12 12 12 12 12 12 12
Power input 12Pa W 35.2 46 57.4 69 86 123 160 189 228
30Pa W 39.5 55 66.9 82 100 136 175 211 247
50Pa W 49.5 59 85.4 93 108 155 188 236 297
Sound pressure Level** 12Pa dB(A) 37 39 41 43 45 46 48 50 52
30Pa dB(A) 40 42 44 46 47 48 50 52 54
50Pa dB(A) 42 44 46 47 49 50 52 54 56
Net weight kg 10.5 14.6 16 16.5 18.5 23.5 25.5 30.5 35.5
Water flow rate m3/h 0.4 0.51 0.71 0.92 1.05 1.4 1.75 2.1 2.5
Water pressure drop kPa 20 20 25 30 35 40 40 45 50
Water connections Inch RC 3/4
Drain pipe Inch RC 3/4
Fan motor quantity Nr. 1 1 1 1 1 2 2 2 2
Fan quantity Nr. 1 2 2 2 2 3 4 4 4
Max. working pressure Mpa 2
Power supply / 220V/1Ph/50Hz


*The data are referred to the following conditions:

Cooling: room temperature: 27°C 50% RH, water temperature: 7/12°C, high speed.

Heating: room temperature: 21°C, water temperature: 45/40°C, high speed.

Request For Quotation