Wide Operation Range

The unit could operate perfectly between 52°C in hot summer and -15°C in cold winter making you feel like spring all year around with advanced system design and strict matching test(cooling in -15°C ).


DC Inverter Compressor

Made of rare earth permanent magnetic material, the rotor could change the motor’s round speed by changing the DC voltage motor, thus overcome the electromagnetic noise and rotor loss of AC inverter compressor, then achieves high efficiency as well as low noise.



Auto Restart Function

The AC can automatically memorize the operation setting when power is cut off accidently. It can return to previous setting when power resumes.

Recover the former operation state when power is restored, no need restart the unit manually.


Fast Cooling/Heating Technology

The DC Inverter Compressor system reaches full load rapidly providing less temperature fluctuation and an improved living environment, bringing great user experience.



Accurate Temperature Control

According to change trend of indoor ambient temperature, the unit can use PI algorithm to calculate capacity demand percentage of indoor unit, control operating frequency of compressor in real time and reach accurate control of room temperature.



Flexible And Diversified Matching Of Indoor And Outdoor Unit

Amrta offers a variety indoor units, more than 100 models of 7 types. Capacity ranges are from 2.2Kw to 14Kw. It is full compliance with residential and light commercial place. Our systems can operate up to 130% of capacity which allows any system to be designed to the customers and applications needs.


Wide Voltage Design

In country with unstable voltage, ARV can also run stably.

Long Piping Length

Max. Total piping length — 100/150m

Max. Actual piping length — 60/100m

Max. Level diff erence between indoor units — 10/15m

Max. Level diff erence between ODU and IDU units — 40/50m

Max. piping length from 1st indoor branch to the farthest indoor unit — 20m/40m


Technical Data

All DC inverter 50Hz/60Hz

Model Outdoor   ARV-H080/NR1 ARV-H100/NR1 ARV-H120/NR1 ARV-H140/NR1 ARV-H160/NR1
Capacity Cooling kW 8.00  10.00  12.30  14.00  16.00 
Heating kW 9.00  11.50  13.20  16.50  18.00 
Electrical Data Power Supply V~,Hz,Ph 220~240,50/60,1 220~240,50/60,1 220~240,50/60,1 220~240,50/60,1 220~240,50/60,1
Cooling Power Input kW 2.30  3.00  3.25  3.95  4.80 
Heating Power Input kW 2.40  3.20  3.41  4.05  4.80 
Cooling Current A 10.10  13.20  14.30  17.30  21.10 
Heating Current A 10.50  14.00  15.00  17.80  21.10 
EER   3.48  3.33  3.78  3.54  3.33 
COP   3.75  3.59  3.87  4.07  3.75 
SEER   6.20  6.10  6.10  6.10  6.10 
SCOP   4.20  4.10  4.10  4.00  4.00 
Performance Air Flow Volume m³/h 4154  4154  7200  7200  7200 
Noise Level DB(A) 56  56  57  57  57 
Piping Limit Level Difference Between IDU and ODU m 50  50  50  50  50 
Level Difference Between IDU and IDU m 10  10  15  15  15 
Between the First Brance and the Farthest IDU m 40  40  40  40  40 
Total Pipe Length m 100  100  150  150  150 
Max. No. of Indoor Units   unit
Connection Ratio   % 50~130 50~130 50~130 50~130 50~130
Dimension (WxDxH) Net mm 970x395x805 970x395x805 940x370x1325 940x370x1325 940x370x1325
Packing mm 1105x495x895 1105x495x895 1080x430x1440 1080x430x1440 1080x430x1440
Weight Net kg 66  66  86  86  93 
Gross kg 71  71  91  91  98 
Refrigerant Type     R410a R410a R410a R410a R410a
Pipe Diameter Liquid Side mm(inch) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gas Side mm(inch) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) 19.05(3/4)
Operation Range Cooling -15~52 -15~52 -15~52 -15~52 -15~52
Heating -15~27 -15~27 -15~27 -15~27 -15~27
Stuffing Quantity 20/40/40H unit 44/96/144 44/96/144 26/54/54 26/54/54 26/54/54


ARV mini series 50Hz

Model Outdoor ARV-H220/5R1A ARV-H280/5R1A
Cooling
Capacity
Heating
kW kW 22.40
24.50
26.00
28.50
Power Supply V~,Hz,Ph 380~415,50,3 380~415,50,3
Cooling Power Input kW 7.20 8.40
Heating Power Input kW 6.70 7.90
Electric DataCooling Current A 11.60 13.50
Heating Current A 11.00 13.00
EER
3.11 3.10
COP
3.66 3.61
Air Flow Volume
Performance
Noise Level
m3/h dB(A) 9000
60
9000
60
Vertical Pipe Length m ≤30 ≤30
Actual Pipe Length
Piping Limit
Equivalent Pipe Length
m m 45
50
45
50
Total Pipe length m 100 100
Max. No. of Indoor Units unit 11 12
Connection Ratio% 50~130 50~130
DimensionNet mm 1120×400×1510 1120×400×1510
(WxDxH)Packing mm 1270×560×1710 1270×560×1710
Net
Weight
Gross
kg kg 150
170
150
170
Refrigerant Type R410a R410a
Liquid Side
Pipe Diameter
Gas Side
mm(inch) mm(inch) 9.52(3/8)
22.22(7/8)
9.52(3/8)
22.22(7/8)
Cooling
Operation Range
Heating
°C
°C
-10~52
-15~24
-10~52
-15~24
20/40/40H unit 17/37/37 17/37/37

Notes:

1.Cooling Capacity: Indoor temperature 27°C DB/ 19°C WB; Outdoor temperature:35°C DB/ 24°C WB.

2.Cooling Capacity (Tropical): Indoor temperature 27°C DB/19°C WB;Outdoor temperature:46.1°C DB.

3.Heating Capacity: Indoor temperature 20°C DB; Outdoor temperature: 7°C DB/ 6°C WB.

4.Piping Length: Equivalent piping length: 7.5m, level difference: 0m.

5.Anechoic chamber conversion value, measured in test room. During actual operation. These values are normally somewhat higher as a result of ambient conditions.

6.The above designs and specifications are subject to change without prior notice. Final specifications please refer to technical specification provided by sales representative.